科動工業以太網產品常見使用方法
In shared Ethernet networks, repeating hubs and associated cabling all reside in a common collision domain. Expanding the network beyond the maximum allowable collision domain results in unstable operation. When expanding 10 Mbps twisted-pair networks, a maximum of four repeating hubs can be cascaded. Each ![]() |
The restriction that all repeating hubs and associated cabling must reside within the collision domain limits the deployment of fiber optics. However, it is possible to create a network of four repeating hubs and a mix of twisted-pair and fiber optic cabling. The end hubs incorporate twisted-pair cabling, on all ports, while the two inner hubs share a single fiber optic segment which can be up to 2 km in length. ![]() |
A two-port fiber optic model is available in the EI series, which allows for the cascading of three repeating hubs using two fiber optic segments. In order not to violate the collision domain restriction, the two fiber optic segments cannot exceed an accumulative length of 2 km. The number of cascaded hubs![]() |
![]() |
![]() |
![]() allowing for the cascading of more than two switches using fiber optic cabling. Notice that the crossover function is accomplished over the fiber segment by reversing the connections on one side. The fiber optic ports all operate at 100 Mbps and, therefore, should be configured for full-duplex in order to achieve the maximum segment length of 2 km with multimode fiber and 15 km with single-mode fiber. Connectors for multimode can be either ST or SC. For single-mode, only SC connectors are available. |
By dedicating four ports to a trunk, a high-speed backbone between two EISCs can be created. During configuration, ports are assigned to a trunk in groups of four. ![]() |
The EISC is capable of creating either 14 or 15 separate Port VLANs. ![]() |
In transparent mode, two EIMCs are connected back-to-back using a fiber optic cable and their DIP switches are set to transparent mode.![]() and hub C can auto-negotiate, then the two will do so as if they were directly connected. The fiber optic connection is transparent to the operation. In this situation, the data rate, duplex and flowcontrol will be auto-negotiated. If 100 Mbps operation is expected, either the EIMC-100T/FT or EIMC-100T/FC should be used depending upon the type of connectors needed. An EIMC-10T/F cannot communicate with an EIMC-100T/F since the fiber optic operating wavelengths differ. |
Since two fiber optic ports cannot auto-negotiate, it is necessary to set the data rate and flow rate manually. This situation will occur when an EIMC must mate to a fiber optic port on either a hub or switch. Determine the settings of the fiber optic port on the hub or switch.![]() |